Characteristics
Construction
Type : multicore cable
Core : flexible tin-plated copper
Insulation : Varpren® thin wall insulation
Sheath : Varpren® thin wall sheath - type EM 104
Production
Standard : 4x au 37x (depends on cross sections), 0.5 to 2.5 mm²
Options : please consult our data sheet FT 5103
Application
Rolling stock : control and command cables with special fire performance used in protected situations (class P) or exposed situations (class E) as either fixed wiring or wiring with limited flexing operation
General characteristics
Chemical behaviour : very good resistance to acide, base, mineral oil and fuel (only for class M)
Mechanical behaviour : excellent cut-through resistance and excellent abrasion resistance
Bending radius : minimal 5 x D as per EN 50355
Size : compact design with thin insulation
Thermal characteristics
Continuous operating temperature : -40°C to +90°C
Electrical characteristics
OperatingVoltage : 300 / 500V
Test voltage : 2 kV A.C.
Approvals - Standards
Rolling stock : EN 45545-2, NFPA 130, EN 50306-1, EN 50306-2, EN 50306-4
Flame retardant, test on bunched cables : IEC 60332-3-24 / EN 60332-3-24
Flame retardant : IEC 60332-1-2 / EN 60332-1-2 /NF C 32-070 test C2
Halogen free : IEC 60754-1 / EN 60754-1
Low toxicity : IEC 60754-2 / EN 60754-2
Low smoke : IEC 61034-2 / EN 61034-2