Skip to main content
VARPREN RW EN 50306-2 300V M

VARPREN® RW
EN 50306-2 300V M

FT5101

Characteristics

Construction
Type : single core cable
Core : flexible tin-plated copper
Insulation : Varpren® thin wall insulation
Production
Standard : 0.5 to 2.5 mm²
Options : please consult our data sheet FT 5101
Application
Rolling stock : control and command cables with special fire performance used as either fixed wiring or wiring with limited flexing operation
General characteristics
Chemical behaviour : very good resistance to acide, base, mineral oil and fuel (only for class M)
Mechanical behaviour : excellent cut-through resistance and excellent abrasion resistance
Bending radius : minimal 5 x D as per EN 50355
Size : compact design with thin insulation
Thermal characteristics
Continuous operating temperature : -40°C to +105°C
Electrical characteristics
OperatingVoltage : 300 / 500V
Test voltage : 2 kV A.C.
Approvals - Standards
Rolling stock : EN 45545-2, NFPA 130, EN 50306-1, EN 50306-2
Flame retardant, test on bunched cables : IEC 60332-3-24 / EN 60332-3-24
Flame retardant : IEC 60332-1-2 / EN 60332-1-2 /NF C 32-070 test C2
Halogen free : IEC 60754-1 / EN 60754-1
Low toxicity : IEC 60754-2 / EN 60754-2
Low smoke : IEC 61034-2 / EN 61034-2