Characteristics
Construction
Type :
single core cable
Core :
flexible tin-plated copper - class 5 as per IEC 60228
Insulation :
Varpren® fire resistant elastomer - type EI 109 as per EN 50264-3-1
Production
Standard :
1.5 to 300 mm²
Options :
please consult our data sheet FT 5213
Application
Rolling stock :
power cables with special fire performance used inboards safety circuits, lighting circuits, auxiliary circuits
Approvals - Standards
Rolling stock :
EN 50264-1, EN 50264-3-1
Flame retardant, test on bunched cables :
IEC 60332-3-24 / EN 60332-3-24
Flame retardant :
IEC 60332-1-2 / EN 60332-1-2 /NF C 32-070 test C2
Halogen free :
IEC 60754-1 / EN 60754-1
Low toxicity :
IEC 60754-2 / EN 60754-2
Low smoke :
IEC 61034-2 / EN 61034-2
General characteristics
Chemical behaviour :
very good resistance to acide, base, mineral oil and fuel (only for class M)
Mechanical behaviour :
excellent cut-through resistance and excellent abrasion resistance
Bending radius :
minimal 4 x D as per EN 50355
Thermal characteristics
Continuous operating temperature :
-40°C to +90°C
Electrical characteristics
OperatingVoltage :
1.8 / 3 kV
Test voltage :
6.5 kV A.C.