Characteristics
Construction
Type : shielded single core cable
Core : flexible tin-plated copper - class 5 as per IEC 60228
Insulation : Varpren® fire resistant elastomer - type EI 104 as per EN 50264-2-1
Shielding : tin-plated copper braid
Sheath : Varpren® fire resistant elastomer - type EM 104 as per EN 50264-2-1
Production
Standard : 2.5 to 185 mm²
Options : please consult our data sheet FT 5211
Application
Rolling stock : power cables with special fire performance used in medium voltage circuits,, with tin-plated copper braid screen
General characteristics
Chemical behaviour : very good resistance to acide, base, mineral oil and fuel (only for class M)
Mechanical behaviour : excellent cut-through resistance and excellent abrasion resistance
Bending radius : minimal 10 x D as per EN 50355
Thermal characteristics
Continuous operating temperature : -40°C to +90°C
Electrical characteristics
OperatingVoltage : 3.6 / 6 kV
Test voltage : 11 kV A.C.
Approvals - Standards
Rolling stock : EN 50264-1, EN 50264-2-1
Flame retardant, test on bunched cables : IEC 60332-3-24 / EN 60332-3-24
Flame retardant : IEC 60332-1-2 / EN 60332-1-2 /NF C 32-070 test C2
Halogen free : IEC 60754-1 / EN 60754-1
Low toxicity : IEC 60754-2 / EN 60754-2
Low smoke : IEC 61034-2 / EN 61034-2