Characteristics
Construction
Type : multi-pair cable
Core : rigid bare copper
Insulation : Skin Foam Skin polyethylene
Electrical screen : aluminium/PET tape, continuity wire
Shielding : tin-plated copper braid
Other : cross filler
Sheath : halogen free thermoplastic
Production
Standard : 4 p 23 AWG, 2 x 4 p 23 AWG
Packaging : Couronnes. Boîtes 305 mètres. Bobines. Tourets
Options : please consult our data sheet FT 6087
Application
Construction and infrastructure : VDI networks (Voice / Data / Image)
General characteristics
Data transmission : maximum attenuation at 500 MHz: 45.3 dB/100m, for further information please consult our data sheet
Thermal characteristics
Continuous operating temperature : -20°C to +70°C
Electrical characteristics
Impedance : 100 ohms +/- 15 ohms (1 to 100 MHz), +/- 20 ohms (100 to 250 MHz), +/- 25 ohms (250 to 500 MHz)
Approvals - Standards
CPR cable class : EN 50575 Dca-s2,d2,a2
Construction : IEC 61156-5, NF EN 50288-10-1
Halogen free : IEC 60754-1 / EN 60754-1
Low toxicity : IEC 60754-2 / EN 60754-2
Low smoke : IEC 61034-2 / EN 61034-2