Characteristics
Construction
Type :
electrical wire
Core :
flexible bare (FEP) or tin-plated (EFEP) copper
Insulation :
fluorinated polymer FEP
Production
Standard :
0.05 to 50 mm²
Options :
please consult our data sheet FT 2106
Application
General use :
cabling in aggressive environments (humidity, chemicals, etc.), cabling requiring compact size and excellent mechanical strength
Electromechanics :
cabling for rotating machines
Household appliances :
cabling for household electrical heating appliances
Other(s) :
cabling in hot or cold environments (cryogenics)
Approvals - Standards
Construction :
series inspired by standards NF C 93-524 and DIN VDE 0250 part 106
General characteristics
Weather conditions :
excellent resistance to UV
Chemical behaviour :
excellent resistance to aggressive chemical environments
Humidity :
excellent resistance to humidity
Mechanical behaviour :
excellent mechanical strength
Size :
compact design with thin insulation
Thermal characteristics
Continuous operating temperature :
-90°C to +205°C
Electrical characteristics
OperatingVoltage :
450 / 750V
Test voltage :
2500 V