Characteristics
Construction
Type : shielded single core cable
Core : flexible tin-plated copper - class 5 as per IEC 60228
Insulation : silicone rubber with high mechanical properties - type EI 111 as per EN 50382-1
Shielding : tin-plated copper braid
Sheath : silicone rubber with high mechanical properties - type EM 107 as per EN 50382-1
Production
Standard : 2.5 to 400 mm²
Options : please consult our data sheet FT 5312
Application
Rolling stock : high temperature power cables with special fire performance for traction and power circuits, with synthetic reinforcing braid within the insulation, tin-plated copper braid screen and extra flexible class 6 tin-plated copper core
General characteristics
Chemical behaviour : very good resistance to acide, base and mineral oil
Mechanical behaviour : excellent cut-through resistance and excellent abrasion resistance
Bending radius : minimal 10 x D as per EN 50355
Motion : very good resistance to alternate bending
Thermal characteristics
Continuous operating temperature : -40°C to +150°C
Electrical characteristics
OperatingVoltage : 3.6 / 6 kV
Test voltage : 11 kV A.C.
Approvals - Standards
Rolling stock : EN 50382-1, EN 50382-2
Flame retardant, test on bunched cables : IEC 60332-3-24 / EN 60332-3-24
Flame retardant : IEC 60332-1-2 / EN 60332-1-2 /NF C 32-070 test C2
Halogen free : IEC 60754-1 / EN 60754-1
Low toxicity : IEC 60754-2 / EN 60754-2
Low smoke : IEC 61034-2 / EN 61034-2