Characteristics
Construction
Type : multicore cable
Core : flexible tin-plated copper - class 5 as per IEC 60228
Insulation : silicone rubber
Reinforcing braid : coated fiberglass braid
Sheath : silicone rubber
Production
Standard : 2x au 19x, in 0.5 and 0.75 mm²
Options : please consult our data sheet FT 1220
Application
Industry : industrial cabling in hot atmospheres
Electromechanics : cabling for rotating machines (motors, alternators, generators)
Lighting : lights, spotlights, etc
Electrical engineering : cabling for rotating machines (motors, alternators, generators) and power cabinets
Marine, naval : shipbuilding construction
Heavy industry : foundries, steelworks, glassworks, etc.
Rolling stock : cabling for railway construction
General characteristics
Operating environment : good resistance to thermal shock
Weather conditions : good resistance to UV
Mechanical behaviour : excellent mechanical strength
Thermal characteristics
Continuous operating temperature : -60°C to +180°C
Electrical characteristics
OperatingVoltage : 600 / 1000V
Test voltage : 3000 V
Approvals - Standards
Fire retardant : NF C 32-070 test C1
Flame retardant : IEC 60332-1-2 / EN 60332-1-2 /NF C 32-070 test C2
Fire resitance, circuit integrity : IEC 60331-21
Halogen free : IEC 60754-1 / EN 60754-1
Low toxicity : IEC 60754-2 / EN 60754-2
Low smoke : IEC 61034-2 / EN 61034-2