Characteristics
Construction
Type :
ignition cable
Core :
flexible tin-plated copper - class 5 as per IEC 60228/ DIN VDE 0295
Insulation :
silicone rubber - type EI2 - DIN EN 50363-1
Production
Standard :
0.75, 1 and 1.5 mm²
Options :
please consult our data sheet FT 1118
Application
General use :
ignition circuit and creation of an electric arc forgas or oil burners for boilers and professional appliances
Household appliances :
ignition circuit and creation of an electric arc for: piezo-electric components in household electrical appliances
Approvals - Standards
Halogen free :
IEC 60754-1 / EN 60754-1
VDE approval :
licence (please consult our data sheet)
General characteristics
Operating environment :
good resistance to thermal shock
Weather conditions :
good resistance to UV
Thermal characteristics
Continuous operating temperature :
-60°C to +180°C
Electrical characteristics
OperatingVoltage :
1.8 / 3 kV
Pulse voltage :
10 kV