Characteristics
Construction
Type :
thermocouple cable
Couple(s) :
JX, TX, KX, EX, BC, KCB
Insulation :
silicone rubber as per NF C 32-090
Electrical screen :
optional: please consult our data sheet for further information
Shielding :
optional: please consult our data sheet
Armour :
optional: please consult our data sheet
Sheath :
silicone rubber
Category :
extension cable - tolerance class: 1, compensation cable - tolerance class: 2
Colour of outer cable sheath :
IEC
Production
Standard :
1 to 37 pairs, 0.5 / 1 mm²
Options :
please consult our data sheet FT 6205
Approvals - Standards
Fire resistance :
IEC 60331-21 / EN 50200
Fire retardant :
NF C 32-070 test C1
Flame retardant, test on bunched cables :
IEC 60332-3-22 / EN 60332-3-22
Flame retardant :
IEC 60332-1-2 / EN 60332-1-2 /NF C 32-070 test C2
Halogen free :
IEC 60754-1 / EN 60754-1
Low toxicity :
IEC 60754-2 / EN 60754-2
Low smoke :
IEC 61034-2 / EN 61034-2
Temperature measurement :
IEC 60584-1, IEC 60584-2, IEC 60584-3
General characteristics
Weather conditions :
resistance to UV ≥ 2000 hours as per EN 1647
Chemical behaviour :
good resistance to acid and base, excellent resistance to aliphatic hydrocarbons and mineral oil
Resistance to water :
type AD7 as per IEC 60529 without immersion of ends
Thermal characteristics
Continuous operating temperature :
-60°C to +200°C
Electrical characteristics
Test voltage :
500V