PROFIPLAST®
Reference
CABLETTE
Material : stranded bare copper core
Resistance : hydrocarbons
PROFIPLAST®
Reference
H05V-U
Temperature : - 5°C to + 70°C
Rated voltage : 300/500 V
Material : PVC
Approval : RPC EN 50575, <HAR>
PROFIPLAST®
Reference
H05V2-U
Temperature : - 5°C to + 90°C
Rated voltage : 300/500 V
Material : PVC
Approval : <HAR>
PROFIPLAST®
Reference
H07V-U
Temperature : - 5°C to + 70°C
Rated voltage : 450/750 V
Material : PVC
Approval : RPC EN 50575, <HAR>
PROFIPLAST®
Reference
H07V2-U
Temperature : - 5°C to + 90°C
Rated voltage : 450/750 V
Material : PVC
Approval : <HAR>
PROFIPLAST®
Reference
H07V-R
Temperature : - 5°C to + 70°C
Rated voltage : 450/750 V
Material : PVC
Approval : RPC EN 50575, <HAR>
PROFIPLAST®
Reference
07V2-R
Temperature : - 5°C to + 90°C
Rated voltage : 450/750 V
Material : PVC
PROFIPLAST®
Reference
H05V-K
Temperature : - 5°C to + 70°C
Rated voltage : 300/500 V
Material : PVC
Approval : RPC EN 50575, <HAR>
PROFIPLAST®
Reference
H05V2-K
Temperature : - 5°C to + 90°C
Rated voltage : 300/500 V
Material : PVC
Approval : <HAR>
PROFIPLAST®
Reference
H07V-K
Temperature : - 5°C to + 70°C
Rated voltage : 450/750 V
Material : PVC
Approval : RPC EN 50575, <HAR>
PROFIPLAST®
Reference
H07V2-K
Temperature : - 5°C to + 90°C
Rated voltage : 450/750 V
Material : PVC
Approval : RPC EN 50575, <HAR>
PROFIPLAST®
Reference
SV-HT 105
Temperature : - 25°C to + 105°C
Rated voltage : 300/500 V, 450/750 V
Material : PVC
PROFIPLAST®
Reference
SV-THT 125
Temperature : - 25°C to + 125°C
Rated voltage : 300/500 V, 450/750 V
Material : PVC
PROFIPLAST®
Reference
05Z1-K
Temperature : - 5°C to + 70°C
Rated voltage : 300/500 V
Material : halogen free
PROFIPLAST®
Reference
07Z1-K
Temperature : - 5°C to + 70°C
Rated voltage : 450/750 V
Material : halogen free
PROFIPLAST®
Reference
FR-N07V-AR
Temperature : - 5°C to + 70°C
Rated voltage : 450/750 V
Material : PVC
Core : aluminium (16, 25, 35 mm²)
Approval : RPC EN 50575, NF USE
PROFIPLAST®
Reference
TWISTE
Temperature : - 5°C to + 70°C
Rated voltage : 450/750 V
Material : PVC
Version : twisted
PROFIPLAST®
Reference
FR-N05VV-U
Temperature : - 5°C to + 70°C
Rated voltage : 300/500 V
Material : PVC
Approval : NF USE
PROFIPLAST®
Reference
H03VV-F
Temperature : - 5°C to + 60°C
Rated voltage : 300/300 V
Material : PVC
Approval : <HAR>
PROFIPLAST®
Reference
H03V2V2-F
Temperature : - 5°C to + 90°C
Rated voltage : 300/300 V
Material : PVC
PROFIPLAST®
Reference
H05VV-F
Temperature : - 5°C to + 60°C
Rated voltage : 300/500 V
Material : PVC
Approval : <HAR>
PROFIPLAST®
Reference
H05V2V2-F
Temperature : - 5°C to + 90°C
Rated voltage : 300/500 V
Material : PVC
Approval : <HAR>
PROFIPLAST®
Reference
CSR
Temperature : - 15°C to + 70°C
Rated voltage : 300/500 V
Material : PVC
PROFIPLAST®
Reference
CSR-HT
Temperature : - 25°C to + 105°C
Rated voltage : 600/1000 V
Material : PVC
PROFIPLAST®
Reference
CSR LSZH
Temperature : - 20°C to + 70°C
Rated voltage : 300/500 V
Material : halogen free
PROFIPLAST®
Reference
CSR BPA
Temperature : - 15°C to + 70°C
Rated voltage : 300/500 V
Material : PVC
Version : sreened
PROFIPLAST®
Reference
CSR BE
Temperature : - 15°C to + 70°C
Rated voltage : 300/500 V
Material : PVC
Shielding : tin-plated copper braid
PROFIPLAST®
Reference
03Z1Z1-F
Temperature : - 5°C to + 60°C
Rated voltage : 300/300 V
Material : halogen free
PROFIPLAST®
Reference
05Z1Z1-F
Temperature : - 5°C to + 60°C
Rated voltage : 300/500 V
Material : halogen free
PROFIPLAST®
Reference
H03VVH2-F
Temperature : - 5°C to + 60°C
Rated voltage : 300/300 V
Material : PVC
Version : flat cable
Approval : <HAR>
LUMIPLAST®
Reference
03VH-H
Temperature : - 5°C to + 60°C
Rated voltage : 300/300 V
Material : PVC
Version : 2-conductor
PROFIPLAST®
Reference
U1000 R02V
Temperature : - 25°C to + 90°C
Rated voltage : 600/1000 V
Material : PVC
Approval : RPC EN 50575
BIO-HABITAT®
Reference
H07V-U BPA
Temperature : - 5°C to + 70°C
Rated voltage : 450/750 V
Material : PVC
Version : screened
Approval : RPC EN 50575
BIO-HABITAT®
Reference
H07V-R BPA
Temperature : - 5°C to + 70°C
Rated voltage : 450/750 V
Material : PVC
Version : screened
Approval : RPC EN 50575
BIO-HABITAT®
Reference
H07Z-U BPA
Temperature : - 5°C to + 70°C
Rated voltage : 450/750 V
Material : halogen free
Version : screened
Approval : RPC EN 50575
BIO-HABITAT®
Reference
05VV-U BPA
Temperature : - 5°C to + 70°C
Rated voltage : 300/500 V
Material : PVC
Version : screened
Approval : RPC EN 50575
BIO-HABITAT®
Reference
H05VV-F BPA
Temperature : - 5°C to + 70°C
Rated voltage : 300/500 V
Material : PVC
Version : screened
Approval : RPC EN 50575
PROFIPLAST®
Reference
10V2-K
Temperature : - 25°C to + 105°C
Rated voltage : 600/1000 V
Material : PVC 105°C
PROFIPLAST®
Reference
10Z1-K
Temperature : - 25°C to + 105°C
Rated voltage : 600/1000 V
Material : halogen free
PROFIPLAST®
Reference
1000 YY
Temperature : - 15°C to + 70°C
Rated voltage : 600/1000 V
Material : PVC
PROFIPLAST®
Reference
1000 YCY
Temperature : - 15°C to + 70°C
Rated voltage : 600/1000 V
Material : PVC
Shielding : tin-plated copper braid
PROFIPLAST®
Reference
1000 YwCYw
Temperature : - 25°C to + 105°C
Rated voltage : 600/1000 V
Material : PVC
Shielding : tin-plated copper braid
PROFIPLAST®
Reference
1000 YCY LSLH
Temperature : - 15°C to + 70°C
Rated voltage : 600/1000 V
Material : PVC LSLH
Shielding : tin-plated copper braid
PROFIPLAST®
Reference
1000 LSZH
Temperature : - 15°C to + 70°C
Rated voltage : 600/1000 V
Material : halogen free
PROFIPLAST®
Reference
1000 LSZH BE
Temperature : - 15°C to + 70°C
Rated voltage : 600/1000 V
Material : halogen free
Shielding : tin-plated copper braid
PROFIPLAST®
Reference
1000 YCYRHC1
Temperature : - 15°C to + 70°C
Rated voltage : 600/1000 V
Material : PVC HR
Shielding : tin-plated copper braid
Version : oil resitant
PROFIPLAST®
Reference
1000 YCY LSLH C1
Temperature : - 5°C to + 60°C
Rated voltage : 600/1000 V
Material : PVC LSLH
Shielding : tin-plated copper braid
PROFIPLAST®
Reference
1000 2YSLCY-J
Temperature : - 5°C to + 70°C
Rated voltage : 600/1000 V
Material : PVC
Version : shielded (tape and braid)
PROFIPLAST®
Reference
1000 GVS RH
Temperature : - 20°C to + 60°C
Rated voltage : 600/1000 V
Material : PVC HR
Core : tin-plated copper
Resistance : hydrocarbons
PROFIPLAST®
Reference
07V-K6 HT
Temperature : - 25°C to + 105°C
Rated voltage : 450/750 V
Material : extra flexible PVC
Core : classe 6, extra flexible
A question, an information?
Contact our team
Contactez-nous